Located in Busan, south korea

INFORMATION SHEARING

To Meet TOMATOENC is To Be World Class!

Information Shearing

◌ How to apply seismic Load to API 620 Storage Tank (2) (ANSYS)
첨부파일 FEA for Anchor Strap.pdf (0) Size : 1.7 Mb Date 2019.01.30 Hits 1220

keywords:

Seismic Load, Convective, Impulsive, API620, LPG storage Tank, Single Containtment Storage Tank, ANSYS, Limit Load

 

I want to introduce how to apply seismic load to API 620 storage tank to calculate anchor strap by using ANSYS.

Key contents of this document is the way to calculate siesmic load and apply seismic load in ANSYS.

Refer to attached PDF file.

 

(Attached file is available freely for non-commercial, but not freely for any commercial use)